Hamco67 B Freezing Point Apparatus with Refrigerated Cooling As Per ASTM D 1177

Test Method : The freezing point of an aviation fuel is the lowest temperature at which the fuel remains free of solid hydrocarbon crystals that can restrict the flow of fuel. The temperature of the fuel in the aircraft tank normally falls during flight depending upon aircraft speed, altitude, and flight duration. The freezing point of the fuel must be lower than the minimum operational tank temperature. The test determines the temperature below which solid hydrocarbon crystals form in aviation fuels. The sample is cooled with continuous stirring in a dewar-type sample tube until crystals appear.

Conforms to ASTM d1177 specifications.
  • 1) Type of chamber : Mechanically refrigerated cooled cascade type.
  • 2) Cooling stage : Double stage with double compressor.
  • 3) Refrigerant : CFC free.
  • 4) Max working temperature : -55 degree c
  • 5) Compartment : Single
  • 6) Chamber : 4 chamber of copper immersed fully in cooling media.
  • 7) Insulation : Dense puff.
  • 8) Top insulation will be done by polyurethane sheet with Bakelite mounting.
  • 9) Chamber cover : Made of PP with Bakelite knob having center hole.
  • 10) Mounting : Floor mounted.
  • 11) Movability : Mounted on four castor wheel with brakes on two front wheel for easy movability.
  • 12) Accuracy : +/- 2 degree c
  • 13) Readability : +/- 0.1 degree c
  • 14) Temperature Controller :-
  • a. TEMP. IS CONTROLLED BY MICROPROCESSOR BASED PID TEMP. CONTROLLER ,
  • b. IT IS HAVING DUAL DISPLAY WITH LNT OR SIEMENS CONTACTOR FOR SWITCHING ON & SWITCHING OFF THE HEATER.
  • 15) Input power supply: 230 v ac, 50 Hz, 1 phase with 10 amp current rating.
  • 16) Cooling load: 2.5 Kw.
  • 17) Thermocouple :-
  • a. CALIBRATED RTD TYPE THERMOCOUPLE WILL BE PROVIDED CAPABLE OF MEASURING UPTO -100 DEG C AT ACCURACY OF +/- 0.1 DEG C
  • 18) CONTROL PANEL/DISPLAY :-
  • a. DIGITAL DISPLAY FOR PRESENT , SET TEMPERATURES .
  • b. ANALOGUE DISPLAY FOR SUPPLY VOLTAGE
  • c. ANALOGUE DISPLAY FOR COMPRESSOR LOAD
  • d. FUSE FOR OVERLOAD PROTECTION.
  • e. MAIN SWITCH ON/OFF INDICATOR.
  • 19) SAFETY INTERLOCKS/ RELAY :-
  • a. OVERLOAD SAFETY CUT-OFF
  • b. SAFETY FOR INPUT POWER FLUCTUATION
  • c. 1-PHASE INDICATION LAMP.
  • d. EMERGENCY SWITCH OFF
  • 20) CONSTRUCTION :-
  • a. DOUBLE WALLED CONSTRUCTION , THERMALLY INSULATED WITH PUFF FOR BETTER PERFORMANCE DURING CONTINOUS OPERATION.
  • b. POWDER COATED EXTERNAL SURFACE FOR ESTHATIC APPEARANCE.
  • c. DRAIN , OVERFLOW AND FILL VALVE WILL BE PROVIDED.
  • 220-240v, 50/60hz, single phase, 12a
  • 115v, 50/60hz, single phase, 24a

Dimension : Ixwxh,in.(cm)

  • 17”x24”x41” (43x60x104)
  • net weight: 125 Lbs (57 kg)

Shipping Information :

  • Shipping weight: 165 lbs (75 kg)
  • dimensions: 22 cu. Ft.

Ordering Information:

CATALOGUE NO PRODUCT DESCRIPTION ELECTRICAL REQUIREMENT
Hamco 67B Freezing point apparatus refrigerated cooling 230v, 50/60 Hz, 10a
Hamco 67B Exp. Freezing point apparatus refrigerated cooling 115v, 50/60 Hz , 20a