HAMCO39 COLD FINGURE PLUGGING POINT APPARATUS ( CFPP) AS PER ASTM D 6371
Test Method : Determines the low temperature flow characteristics of automotive diesel fuels and gas oils, including samples with flow improving additives, by measuring the temperature at which the sample ceases to flow through a wire mesh filter under standard test conditions. Complete test consists of Cold Filter Plugging Point Apparatus, Vacuum System and Cooling Bath.
Conforms to ASTM D6371, IP 309 and DIN 51428 specifications
- Choice of mechanically refrigerated or dry ice cooled bath
- 1) TYPE OF CHAMBER :- MECHANICALLY REFRIGERATED COOLED CASCADE TYPE
- 2) COOLING STAGE : DOUBLE STAGE WITH DOUBLE COMPRESSOR.
- 3) REFRIGERANT : CFC FREE.
- 4) MAX WORKING TEMPERATURE :- -55 DEGREE C
- 5) COMPARTMENT :- SINGLE
- 6) CHAMBER : 4 CHAMBER OF COPPER IMMERSED FULLY IN COOLING MEDIA.
- 7) INSULATION :- DENSE PUFF.
- 8) TOP INSULATION WILL BE DONE BY POLYURATHENE SHEET WITH BACKELITE MOUNTING.
- 9) CHAMBER COVER:- MADE OF PP WITH BACKELITE KNOB HAVING CENTRE HOLE.
- 10) MOUNTING : FLOOR MOUNTED.
- 11) MOVABILITY : MOUNTED ON FOUR CASTOR WHEEL WITH BRAKES ON TWO FRONT WHEEL FOR EASY MOVABILITY.
- 12) ACCURACY :- +/- 2 DEGREE C
- 13) READABILITY :- +/- 0.1 DEGREE C
- 14) TEMPERATURE CONTROLLER : –
- a. TEMP. IS CONTROLLED BY MICROPROCESSOR BASED PID TEMP. CONTROLLER ,
- b. IT IS HAVING DUAL DISPLAY WITH LNT OR SIEMENS CONTACTOR FOR SWITCHING ON & SWITCHING OFF THE HEATER.
- 15) INPUT POWER SUPPLY : 230 V AC, 50 HZ, 1 PHASE WITH 10 AMP CURRENT RATING.
- 16) COOLING LOAD : 2.5 KW .
- 17) THERMOCOUPLE :-
- a. CALIBRATED RTD TYPE THERMOCOUPLE WILL BE PROVIDED CAPABLE OF MEASURING UPTO -100 DEG C AT ACCURACY OF +/- 0.1 DEG C
- 18) CONTROL PANEL/DISPLAY :-
- a. DIGITAL DISPLAY FOR PRESENT , SET TEMPERATURES .
- b. ANALOGUE DISPLAY FOR SUPPLY VOLTAGE
- c. ANALOGUE DISPLAY FOR COMPRESSOR LOAD
- d. FUSE FOR OVERLOAD PROTECTION.
- e. MAIN SWITCH ON/OFF INDICATOR.
- 19) SAFETY INTERLOCKS/ RELAY :-
- a. OVERLOAD SAFETY CUT-OFF
- b. SAFETY FOR INPUT POWER FLUCTUATION
- c. 1-PHASE INDICATION LAMP.
- d. EMERGENCY SWITCH OFF
- 20) CONSTRUCTION :-
- a. DOUBLE WALLED CONSTRUCTION , THERMALLY INSULATED WITH PUFF FOR BETTER PERFORMANCE DURING CONTINOUS OPERATION.
- b. POWDER COATED EXTERNAL SURFACE FOR ESTHATIC APPEARANCE.
- c. DRAIN , OVERFLOW AND FILL VALVE WILL BE PROVIDED.
SPECIFICATION OF THE COLD FINGURE PLUGGING POINT APPARATUS
Includes Borosilicate test jar with graduation, brass jacket with plastic support ring, plastic stopper, plastic insulating ring and spacer, pipette and brass filter unit with stainless steel fine wire mesh screen.
SPECIFICATION OF THE VACCUM SYSTEM
Connects to Cold Filter Plugging Point Apparatus to draw sample through filter screen. Consists of U-tube Manometer (without mercury), three-way stopcock, air vent tube, cork stopper with elbows, and large glass bottle. Vacuum pump of capacity 15 litre per hour
SPECIFICATION OF THE DRY ICE REFRIGERATION BATH INSTEAD OF MECHANICAL REFRIGERATION BATH :
- Dry-ice model includes insulated copper interior and steel exterior with corrosion resistant polyurethane enamel finish. Composition top plate suspends Cold Filter Plugging Point Apparatus in freezing mixture at the required depth. Handles on exterior permit easy emptying of freezing mixture. Supplied with thermometer holder.
Electrical Requirement :
- 220-240V, 50/60Hz, Single Phase, 15.0A
- 115V, 50/60Hz, Single Phase, 30.0A
Dimension : Ixwxh,in.(cm)
- 15”x15”x27” (39x39x69)
- Net Weight: 64 lbs (29kg)
Shipping Information :
- Shipping weight: 78 LBS (35kg)
- Dimensions: 8.2 Cu. ft.
Ordering Information:
CATALOGUE NO | PRODUCT DESCRIPTION | ELECTRICAL REQUIREMENT |
---|---|---|
HAMCO 39A | CFPP APPARATUS WITH DRY ICE COOLING BATH | 220-240V, 50/60Hz |
HAMCO 39B | CFPP APPARATUS WITH MECHANICALLY REFRIERATED BATH | 220-240V, 50/60Hz |
HAMCO 39B EXP | CFPP APPARATUS WITH MECHANICALLY REFRIERATED BATH | 115V, 60Hz |