Saybolt Viscometer
Test Method : Determines the time required for 60mL of sample to flow through a calibrated orifice under precisely controlled conditions. Saybolt Universal Seconds (SUS) is the standard measurement for lubricants, insulating oils, and lighter fuel grades, and Saybolt Furl Seconds (SFS) is used for heavier oils and bitumen’s.
Standard : Conforms to the specifications of ASTM D 88
- Type Of Bath: Electrically Heated Immersion Heater.
- Max Working Temperature: – 99 Degree C
- Continuous Working Temperature: – 95 Degree C
- Capacity: 1 Sample at A Time.
- Heater: Ss Tubular Immersion Heater
- Accuracy: +/- 3 Degree C
- Readability: +/- 0.5 Degree C
- Temperature Controller : By Energy Regulator Which Will Turn On & Off Heater as Time Switch.
- Input Power Supply: 230 V Ac, 50 Hz, 1 Phase with 6 Amp Current Rating.
- Heating Load: 1 Kw.
- Stirrer: Manual Stirrer with Stirrer Blade for Maintaining Uniformity throughout Chamber.
- Top Lid Made Of Stainless Steel With Provision Of Mounting Of One Thermometer.
- Control Panel/Display :
- A. Energy Regulator.
- B. Heater Indicator.
- C. Kettle Plug for Heater Connection.
- Construction :
- A. Single Walled Construction, Thermally Insulated With Inside Body Made Of Stainless Steel.
- B. Cooling Arrangement Has Been Provided.
- Ss Lid Cover –1 No (Cat No Hamco 37ac1)
- Thermometer Collar — 1 No (Cat No Hamco 37ac2)
- Rubber Lock – 1 No. (Cat No Hamco 37ac3)
- Glass Saybolt Cup — 1 No. (Cat No Hamco 37ac4)
- Thermometer IPASTM 22c With Cal Cert – 1 No. (Cat No Hamco37ac5)
- Digital Stopwatch – 1 No (Cat No Hamco37ac6)
Spares Required For 5 Year Trouble Free Operation :
- Ss Immersion Heater 1 No. (Cat No Hamco37s1)
- Glass Saybolt Cup 1 No. (Cat No Hamco 37ac5)
Electrical Requirement :
- 220-240v, 50/60 Hz, Single Phase, 6.0a
- Or 115v, 50/60hz, Single Phase, 12.0a
Dimension : Ixwxh,in.(cm)
- 9”x9”x18” (23x23x46)
- Net Weight: 12 lbs (5.5kg)
Shipping Information :
- Shipping Weight : 26.4 lbs (12kg)
- Dimensions : 2.2 Cu. ft.
Ordering Information :
CATALOGUE NO | PRODUCT DESCRIPTION | ELECTRICAL REQUIREMENT |
---|---|---|
Hamco 37 A | Saybolt Viscometer With Energy Regulator With Hand Stirrer | 220-240v, 50/60hz, 6.0 Amp |
Hamco 37 A Exp | Saybolt Viscometer With Energy Regulator With Hand Stirrer | 115v, 50/60hz, 12.0 Amp |
Optional Accessory Ordering Information :
CATALOGUE NO | PRODUCT DESCRIPTION |
---|---|
Hamco 37 AC 1 | SS Lid Cover |
Hamco 37 AC 2 | Thermometer Collar |
Hamco 37 AC 3 | Rubber Lock |
Hamco 37 AC 4 | Glass Saybolt Cup |
Hamco 37 AC 5 | Thermometer Astm 22c |
Hamco 37 AC 6 | Digital Stopwatch |
Spares Ordering Information :
CATALOGUE NO | PRODUCT DESCRIPTION |
---|---|
Hamco 33 S1 | Ss Immersion Heater |
Preinstallation requisite (at buyer’s scope)
- Distilled water – 6 ltr.
- Sample 200ml
- Washing solvent.
Note: Saybolt viscometer manufacturer.