What is the Cleveland open cup (COC) Flash point Tester? :-

  • The Cleveland Open Cup (COC) flash point tester is a device used to measure the flash point of a flammable liquid. Flash point is the lowest temperature at which a liquid can produce enough vapor to ignite in the presence of an ignition source.
  • The COC flash point tester works by heating a sample of the liquid in a cup until it reaches a certain temperature. A small flame is then passed over the surface of the liquid, and the temperature at which the vapor above the liquid ignites is recorded as the flash point.

What is the use of COC Flash point tester ? :-

  • The COC flash point tester is commonly used in industries that deal with flammable liquids, such as oil and gas, chemical manufacturing, and transportation. It is an important tool for ensuring the safety of workers and the public when handling and transporting flammable liquids.

What is the Application of COC open cup Flash Point tester? :-

The Automatic Cleveland Open Cup (COC) flash point tester has several applications in industries that deal with flammable liquids. Here are some of the main applications

  • Safety testing: The COC flash point tester is used to determine the flash point of a liquid, which is an important safety parameter. Knowing the flash point helps to ensure that the liquid is stored, transported, and handled safely, reducing the risk of fire and explosions.
  • Quality control: The COC flash point of a liquid can also be an indicator of its quality. If the flash point is too low, it may indicate that the liquid contains impurities or has degraded over time.
  • Regulatory compliance: Many industries are subject to regulations that require them to test the flash point of their products or materials. The Automatic COC flash point tester can be used to ensure compliance with these regulations.
  • Research and development: The COC flash point tester can also be used in research and development to study the properties of different liquids and how they behave under different conditions. This information can be used to develop new products and improve existing ones.
  • Fire Investigation: The Automatic COC flash point tester can be used in fire investigation to determine the flash point of a liquid that was involved in a fire. This information can help to determine the cause of the fire and prevent similar incidents in the future.

What is the standard Cleveland Open cup flash point apparatus follows :-

  • ASTM D92; IP 36; ISO 2592

What are the features of HAMCO Automatic COC Flash point tester ?

  • It is fully automatic open cup flash point tester.
  • It runs both on Gas and electrical ignition Mode.
  • Automatic Cleveland open cup flash point tester is having facility to detect fire point also.
  • Automatic Cleveland open cup flash point tester having fire lid which will automatically activate if fire has been detected. Make it much more safer to use.
  • It has inbuilt Fire lid which extinguish fire in case of any. Make it very safe to use.
  • It is touch screen Colour display PLC Based control system.
  • Inbuilt Memory with 1000 data storage Memory.
  • Inbuilt Thermal printer which prints the data automatically after detection of the Flash point.
  • If it runs on electrical ignition mode than Gas or LPG is not required and it makes it use much more safer.
  • If it runs on Gas Mode, Hamco will provide you the butane gas cartridge where you can test 50 samples in one butane cartridge and as its volume is low it makes it much more safer.
  • Hamco provides standard sample along with the equipment to validate the instruments.
  • In Hamco 19D Automatic COC Flash point apparatus method under ASTM D 92 Flash point apparatus.
  • It is supplied with software which can be used to analyse the data.

Why Hamco ?

  • Hamco has reach experience in designing and manufacturing Automatic COC Flash Point tester since last 10 years. We are having more than 250 successful installation in India and globe. We are strong service support with In house manufacturing and software design capabilities.
  • Hamco is the first one in india to develop the automatic COC flash point apparatus in india and has many more such product in his belt and strongly believe in making high technology products indigenously in india.

Why HAMCO Make Automatic COC Flash Point tester ?

Are you looking for a reliable and accurate way to measure the flash point of your liquid products? Look no further than the Automatic COC Flash Point Tester. Here are some of the benefits of choosing this testing equipment.

  1. Automation and Precision: The HAMCO Make Automatic COC Flash Point Tester is equipped with a Touch screen Colour display PLC , which allows for fully automated flash point determination. This results in precise and consistent results, with minimal operator intervention.
  2. User-Friendly Design: The HAMCO Make Automatic COC Flash Point Tester features a user-friendly interface, with intuitive controls and a large LCD display for easy operation and data reading. The tester also has a compact and ergonomic design, making it easy to use and store.
  3. Safety and Compliance: The Automatic COC Flash Point Tester is designed with safety in mind, with features such as a safety interlock system, flame arrestor, and explosion-proof housing. The tester also complies with international standards such as ASTM D92 and ISO 2592.
  4. Versatility: The Automatic COC Flash Point Tester can be used for a wide range of liquids, including petroleum products, paints and coatings, and chemicals. The tester also supports various test methods, including Rapid test, Open Cup Flash Point test, Manual test, Instrument test etc.
  5. Cost-Effective: The Automatic COC Flash Point Tester offers a cost-effective solution for flash point testing, with its high degree of automation and precision resulting in reduced operator time and improved efficiency.

Investing in an HAMCO Make Automatic COC Flash Point Tester can provide your business with a reliable and accurate way to measure the flash point of your liquid products, while improving efficiency and ensuring compliance with international standards. Contact us today to learn more about our products and how they can benefit your business

What is the difference between Open cup flash point tester and closed cup flash point tester ?

CLOSED CUP FLASH POINT TESTER OPEN CUP FLASH POINT TESTER
The method is Penske-Marten Flash point tester The method is Cleveland Open Cup flash point tester
The temperature range is 40 400 Deg C The temperature range is 79 400 Deg C
It is normally used for Evaporable samples It is normally used for Non Evaporable samples
It is suitable to samples like Diesel, Bio diesel, Transformer Oil etc It is suitable to samples like Engine oil, Hydraulic oil, Lubricating oil etc.
Typically used for Low flash and High volatile samples Typically used for High flash and Low volatile samples
It is Much more safer as the Cup containing sample is sealed with lid and minimal chance to catch fire. Slightly less safer and compulsory to use Fire lid whenever flash detects to make it to more safer. HAMCO Automatic Open cup flash point tester is having this facility.
The ASTM Method it complies is ASTM D 93 The ASTM Method it complies is ASTM D 92

HAMCO19D AUTOMATIC COC FLASH & FIRE POINT TEST APPARATUS WITH TOUCHSCREEN PLC AND FIRE LID AS PER ASTM D 92

TEST METHOD :- Flash Point is Lowest temperature at which application of the ignition source causes the vapour of a specimen of the sample to ignite under the specified condition of the test.

The temperature of the approximately 70 ml test specimen is increased rapidly at first and then at a slower constant rate as the flash point is approached. At specified intervals a test flame is passed across the cup, to measure the tendency of the test specimen to form a flammable mixture with air under controlled laboratory conditions.

HAMCO Make Automatic Cleveland open cup flash point tester is very accurate, precise and safe Instrument to carry out COC Flash point detection by Automatic COC (Cleveland Open Cup) Flash Point Apparatus.

STANDARD :- Conforms to the specifications of:

ASTM D92; IP 36; ISO 2592

FEATURES & BENEFITS :-

  • Range: 79 to 400 deg C.
  • Test Method : ISO 2592 , ASTM D 92 , IP 36 , IS 1448 ( P-69).
  • Test Type :- Automatic Cleveland Open Cup Flash Point tester.
  • Ignition Source : Gas Flame with auto electric Ignitor.
  • Flame Application Mode : Gas or Electric.
  • Fire Lid :- Fire Lid for auto Flame extinguish after Fire detection for safety.
  • Temperature Sensor : PT-100 in stainless steel sheath.
  • Flash/Fire Detector: Ionization principle based flash-detector sensor.
  • Controller: HMI Touchscreen with colour display and Inbuilt storage of approx. 300 sample with audio visual alarm to check the machine. 3-wire RTD

temperature sensor, free potential flame detector sensor as i/p. with automatic barometric reading correction.

  • All necessary interlock for self detection of fault.
  • Flame-Sampling Arrangement: 10 Rpm, D.C. 12 v or 24V DC, gear motor, vertical movement reciprocating to & fro motion.
  • Heater: 800 W, 230 v.
  • Electrical ignition for pilot flame-sampling. Ignition transformer having continuous o/p of 10.6 Kv. D.C. from 230 v A.C. i/p.
  • Equipment Overall Size (LxWxH): 280mm (W) X 530mm ( D ) X 415 mm ( H )
  • Equipment Gross Weight: 22 Kg.
  • Equipment supply will be 230 V Ac , 50 Hz with 15 amp capacity.

FEATURES :-

SINGLE ACTION SETTING :- The Flash Detection ring and temperature sensor are permanently mounted on a swing-arm assembly , which allows easy setting of the specimen.

EASY OPERATION :- Select a Test Mode and enter the expected flash Point . While instrument executes the test , you are free to do other lab work. The tester follows the exact procedures prescribed in the test method and the completion of the test cycle is signalled by buzzer. The test result is brightly shown in VFD.

AUTO FIRE POINT DETECTION : – In addition to the automatic detection of flash point , fire point can be determined automatically too.The fire Point is detected when the ionisation ring detects 5 sec for continous burning.

AUTOMATICALLY SHUT THE MACHINE AND HORN THE BUZZER IN THE CASE:

1 EFP+30oC or at 400oC is reached

2 Temperature sensor is found defective

3 Flash detector is found defective

4 Arm is not set in place

5 Cup is not set in place

6 Heater has gone

7 Side Ignition coil/solenoid has gone

Installation Site : Temperature : 0 to 45 degree C. , Humidity : Less Than 90% ( No condensation).

UTILITY :

  • Power Supply 230 V Ac, 16 amp.
  • GAS Supply ( LP Gas or Natural Gas Pressure Less than 9.8 Kpa)

ACCESSORIES WILL BE SUPPLID WITH EQUIPMENT :-

  • COC CUP — 1 NO (CAT NO HAMCO19AC1)
  • THERMAL PRINTER — 1 NO (CAT NO HAMCO19AC7)
  • THERMAL PRINTER ROLL — 1 NO (CAT NO HAMCO19AC8)
  • PC INTERFACE CABLE 1 NO. (CAT NO HAMCO19AC9)
  • SOFTWARE FOR ABOVE– 1 NO. (CAT NO HAMCO19AC10)
  • ELECTRICAL IGNITOR 1 NO. (CAT NO HAMCO19S3)
  • SIGNAL CABLE – 1 NO. ( CAT NO HAMCO 19AC6)

SPARES REQUIRED FOR 5 YEAR TROUBLE FREE OPERATION :-

  • CERAMIC HEATER — 2 NOS.(CAT NO HAMCO19S1)
  • THERMAL INSULATOR — 1 NO.(CAT NO HAMCO19S2)
  • COC CUP — 2 NO.(CAT NO HAMCO19AC1)
  • ELECTRICAL IGNITOR 1 NO EACH (CAT NO HAMCO19S3)
  • COOLING FAN 1 NO.(CAT NO HAMCO19S4)

ELECTRICAL REQUIREMENT

  • 220-240V, 50/60Hz, Single Phase, 10.9A
  • OR 115V, 50/60Hz, Single Phase, 20.8A

DIMENSION :- Ixwxh,in.(cm)

11x22x17 (28x53x41)

Net Weight: 49 lbs (22kg)

SHIPPING INFORMATION :-

Shipping Weight: 78 lbs (35kg)

Dimensions: 4.7 Cu. ft.

ORDERING INFORMATION :-

CATALOGUE NO PRODUCT DESCRIPTION REQUIREMENT ELECTRICAL
HAMCO 19D AUTOMATIC COC FLASH POINT APPARATUS 220-240V, 50/60Hz
HAMCO 19D EXP AUTOMATIC COC FLASH POINT APPARATUS 115V, 50/60Hz
HAMCO 19S1 CERAMIC HEATER
HAMCO 19S2 THERMAL INSULATOR
HAMCO 19AC1 COC CUP
 

HAMCO 19S3

 

SIDE IGNITOR WITH COIL

 

HAMCO 19S4

 

COOLING FAN

 

Note: flash point apparatus as per astm d 92, open cup flash point tester. We are exports in different countries like Automatic Flash Point Tester in UAE, Oman, Kuwait, Saudi Arabia, Qatar, Nigeria, Angola, Bangladesh, Nepal, Srilanka, Eutopia, South Africa, Iran, Iraq, Myanmar, Sudan, Mauracious, Egypt, Jordan, Morocco, Namibia, Brazil, Philippines, Syria, Tanzania, Thailand, Turkey, Uganda, Vietnam, Yemen.

 